BMYNX - 103A133, 7-STAR WEATHER-SHEDDER LATEX FLAT(

  • MSDS: BMYNX
  • Manufacturer: ACE HARDWARE CORP PAINT DIV
  • Product Name: 103A133, 7-STAR WEATHER-SHEDDER LATEX FLAT(
  • National Stock Number: 8010-00N028981
Product Identification

Product ID:103A133, 7-STAR WEATHER-SHEDDER LATEX FLAT(
MSDS Date:10/01/1986
FSC:8010
NIIN:00N028981
MSDS Number: BMYNX

Responsible Party
ACE HARDWARE CORP/PAINT DIV
21901 SOUTH CENTRAL AVENUE
MATTESON, IL 60443
US

Emergency Phone: 312-720-0600

Info Phone: 312-720-0600

Cage: ACEHA

Contractor
ACE HARDWARE CORPORATION
MATTESON, IL 60443 US

Telephone: 708-720-0600

Cage: ACEHA

Ingredients

0.1

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: 2.0%

OSHA PEL 50 PPM, C

ACGIH TLV: 50 PPM, VAPOR, C

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


SILICA, CRYSTALLINE - CRISTOBALITE

CAS: 14464-46-1

RTECS: VV7325000

Fraction By Weight: 2%

OSHA PEL SEE TABLE Z3

ACGIH TLV: 0.05 MG/M3 RDUST9293


1-PROPANOL, 2-AMINO-2-METHYL;

CAS: 124-68-5

RTECS: UA5950000

Fraction By Weight: <5.0%


3)

CAS: 1333-82-0

RTECS: GB6650000

Fraction By Weight: 7.0%

OSHA PEL 0.01 PPM (CRD*3)

ACGIH TLV: 0.05 MG/ME (CR)

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IN A CONFINED AREA VAPORS IN
HIGH CONCENTRATION ARE ANESTHETIC. IRRITANT TO SKIN AND UPPER
RESPIRATORY SYSTEM. OVEREXPOS MAY RESULT IN LIGHTHEADEDNESS AND
STAGGERING GAIT.
Explanation of Carcinogenicity:CHROMIUM TRIOXIDE:GROUP 1 (NTP, IARC).
SILICA, CRYSTALLINE (CRISTOBALITE): GROUP 2 (NTP), 2A (IARC).
Effects of Overexposure:SEE HLTH HAZ.
Medical Cond Aggravated by Exposure:CHRONIC PROBLEMS WITH RESPIRATORY
SYSTEM MAY BE AGGRAVATED BY EXPOSURE TO VAPORS.

First Aid

First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM AND
QUIET. SKIN:WASH AFFECTED AREAS THOROUGHLY WITH SOAP AND WATER.
REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE RE-USE. EYE:WITH
WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION. INGEST:CALL
MD IMMEDIATELY .

Fire Fighting

Flash Point Method:PMCC
Flash Point:199F,93C
Extinguishing Media:ALCOHOL FOAM, CO2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
H2O SPRAY MAY NOT BE EFTIVE. H2O MAY BE USED TO COOL CLSD CNTNRS TO
PREV PRESS BUILD-UP & POSS(SUPP DATA)
Unusual Fire/Explosion Hazard:EXTREME HEAT MAY CAUSE CLOSED CONTAINERS
TO BURST.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DOL STORAGE CATEGARY-3B
Other Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE. TRANSFER ONLY
TO APPROVED CONTAINERS WITH COMPLETE AND APPROPRIATE LABELING. DO
NOT TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN.

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BE VENTILATION, WEAR RESPIRATORY DEVICE APPROVED
BY NIOSH/MSHA.
Ventilation:LOCAL EXHST PREF, GEN EXHST ACCEPTABLE BELOW TLV OF ING
SECTION, REFER OSHA STDS. 1910.94, 1910.107, 1910.108.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:USE ONLY W/ADEQ VENT. AVOID BREATHING VAPOR AND
SPRAY MIST. AVOID CONTACT WITH SKIN AND EYES. WASH HANDS AFTER
USING.
Supplemental Safety and Health
FIRE FIGHT PROC:AUTO IGNITION OR EXPLOSION WHEN EXPOSED TO EXTREME
HEAT. PART NO/TRADE NAME:FOREST GREEN.

Chemical Properties

HCC:V4
Boiling Pt:B.P. Text:>212F,>100C
Vapor Density:HVR/AIR
Spec Gravity:1.3
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:67.66

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:EXTREME HEAT AND OPEN FLAME.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE AND CARBON
MONOXIDE

Disposal

Waste Disposal Methods:INCINERATE IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS. DISPOSE OF IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL REGULATIONS REGARDING POLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.